Pack Building
Top Balancing LFP Cells
Start every cell at the same full voltage

Cells arrive at slightly different voltages. Joining them in series like that means the pack starts out unbalanced.
Why top balance
LFP cells have a flat voltage curve, so differences hide until the end of charge. A BMS balances only slowly. Starting all cells at the same top-of-charge point gives the BMS far less to correct.
The steps
- Measure and record each cell's voltage.
- Connect all cells in parallel with equal-length connections (positives together, negatives together).
- Charge the parallel group with a bench supply to the cell's full-charge voltage (about 3.65 V for LFP, check the datasheet), allowing the current to taper.
- Hold until current falls to a small value, then rest for hours.
- Disconnect and measure; voltages should now agree closely.
- Assemble in series with series busbars and fit the BMS.
Safety
Use a current-limited supply, cells of the same model, short thick links and constant supervision. Never leave this unattended.
After assembly
A smart BMS such as the Daly ESS 16S shows cell voltages, so you can confirm the pack is in step. See also the cell checklist and compression guide.
General guidance only. Check cell, BMS and strip datasheets and the standards that apply to your product before you build or sell a pack.
Products in this guide
Cells and BMS for a balanced pack
Live stock and price from our store. Tap a product to add it to your quote.
Loading products…
Frequently asked questions
Do I need to top balance every pack?
It is good practice for large cells, especially when cells arrived with different voltages.
How long does it take?
It depends on cell size, supply current and the voltage difference. Large cells can take many hours.
Can the BMS do it for me?
It will balance over time, but a large initial gap can take a very long time to close.